When Auxiliary Equipment Deserves Attention During a Retrofit

An aging pump station does not have to cease operation before it’s a problem. It may still move wastewater or stormwater every day however, it struggles during high demand, require more frequent maintenance, or rely on controls which are becoming more difficult to sustain. The equipment operates, but its original design may not reflect the current conditions surrounding it.

The need to plan infrastructure improvements is vital for city officials, developers and the operators of facilities.

Image credit: romtecutilities.com

The equipment that fails isn’t the only issue

A wastewater lift station retrofit must begin with an evaluation of the complete system, not just the pump which is experiencing difficulties. Engineers must evaluate the wetwell as well as mechanical and electrical components. They should also look at discharge pipes as well as current pumping needs.

The condition of the wet well is particularly important. If its structure is in good condition and in good condition, it could be feasible to keep it in place as a replacement for outdated equipment. It can be less expensive to construct an entirely new station than if you kept the current one. However, maintaining existing infrastructure only makes sense to support the plans for improvements.

Has the Service Area changed?

A water treatment plant built a few many years ago can now provide other commercial or residential properties, homes or industrial processes.

The changes could impact flow rates and operating demands. The rehabilitation of lift stations requires more than just restoring the original equipment specifications. Engineers should assess current and anticipated flows, as well as the equipment’s capacity and dependability.

It’s not enough to just buy a larger pump. The new machine must be compatible with existing piping electrical supply, controls and other components. A mistake in improving one element can lead to problems in other components.

Stormwater Retrofits Have Different Priorities

A stormwater pump station retrofit introduces additional considerations because runoff can change dramatically with rainfall and surrounding development. Stations that service a detention basin could differ in their flow patterns from those that get water from storm drains. The amount of runoff that reaches the station could be affected by new pavements as well as increased parking or a change in drainage infrastructure.

Before recommending an upgrade of a stormwater pumping station, engineers should examine the drainage area of the pump station. They should also review peak flows expected, storage capacity and discharge conditions.

The findings will help you decide if the station has to be renovated or if the modernization of equipment is enough.

Design your project before you cut off service

One frequently overlooked issue is how the current station will be operating during rehabilitation. Systems for managing wastewater generally can’t be disconnected without the need for ongoing flow control.

The construction could include temporary bypass pumps, or the installation of replacement infrastructure along with an operating station depending on the space available and the specific requirements of the project.

It is important to prepare for stormwater projects, as the system could be needed in the event of a sudden rainstorm. The engineering plan should include the installation sequence, temporary operations and equipment integration.

The completed System is more user-friendly

Romtec Utilities offers site-specific engineering solutions and equipment for wastewater and stormwater pumps.

Retrofitting is a process that evaluates structural, mechanical electrical, and communications components to determine which are best kept and which should be replaced. The company provides owners with preliminary plans and estimates of budgets to assist them in evaluating their project options.

Following installation, tests for startup and commissioning takes place and then followed by training for operators and documentation. Operators should be able to keep the station operating and comprehend it after a successful rehabilitation.

Upgrade your system, not only your system’s age

A pump station that is older isn’t always a good candidate to be completely replaced. Even if their electrical or mechanical equipment is old-fashioned Some structures may be of use for a number of years. The crucial thing is to decide what is safe and economically while ensuring that the completed station is able to meet current and future demands.

Owners can make better investment decisions by examining the operating conditions, structural integrity and hydraulic requirements together.

The aim isn’t just to make an aging station work again. It’s to make sure the new system is well-equipped for the work ahead.